For a typical sump pump in storm weather, plan on about 3,200Wh of usable power per day: a pump that draws 800W while it runs, cycling on for the equivalent of about 4 hours a day, uses 800W x 4 hours = 3,200Wh. Because a station delivers about 85 percent of its rated capacity after conversion losses, that day takes a rated capacity of about 3,765Wh. No single station in the seven-station catalog we link to holds that much: the largest, the 2,560Wh BLUETTI Apex 200, covers about 16 hours of that daily pattern per charge, roughly 2.7 hours of actual pump-on time. That is the honest shape of sump pump backup. In lighter rain the same pump may run only 1 to 2 hours a day (800 to 1,600Wh), which the 1,024Wh class or the Delta 2 Max can cover, and in a heavy storm a bigger pump can pass 9,000Wh a day, which no portable station covers. Every figure here is a planning estimate you can adjust to your own pump and your own storm.
This calculator is preloaded with that storm planning case: a sump pump at 800W, 4 hours a day, quantity 1, one day per charge. The 800W figure is the bottom of the 1/3 HP range in our sump pump guide (1/3 HP pumps run about 800 to 1,000W), and the 4 hours is run-time equivalent, explained in the conversion section below: it represents a pump running about 10 minutes per hour around the clock. Change the watts to match your pump label, change the hours for lighter or heavier rain, add a fridge or lights as extra rows if they share the station, and the calculator totals everything, shows the math, and matches you to the smallest station we link to that covers it, or tells you plainly when none does. For a mixed whole-home load, the general Power Station Size Calculator does the same job with a wider preset list.
Every figure on this page is a planning estimate built from manufacturer specifications and the typical published draw ranges used across this site, not a measured result, a hands-on test, or a rating. Real draws vary with your pump model, its age, the water table, and how hard it is raining. One warning belongs up front because it decides more sump pump purchases than capacity does: a pump motor surges hard at startup, and this calculator does not check that surge. The surge section below and our sump pump guide cover how to check it yourself before you buy.
Minutes per hour to hours per day: the conversion
A sump pump does not run continuously. It switches on when the pit fills, empties it, and switches off until it fills again. What the calculator needs is the total pump-on time across a day, and the easiest way to get it is to time one hour during rain: how many minutes in that hour was the pump actually running? Multiply those minutes by 24 and divide by 60 to get hours per day. Five minutes per hour is 2 hours a day. Ten minutes per hour is 4 hours a day, the preloaded case on this page. Fifteen minutes per hour is 6 hours a day. Twenty minutes per hour is about 8 hours a day. Thirty minutes per hour is 12 hours a day, a pump that is running half the time.
Two cautions on that timing. First, it changes with the storm: the same pump might run 2 minutes per hour in light rain and 25 minutes per hour at the peak of a downpour, and the peak is when you can least afford an empty battery. Size for the heavy stretch, not the average day. Second, a pump that suddenly runs much longer per hour than it used to, or never quite catches up, is telling you something about inflow or about the pump itself; no calculator fixes that, and a station sized off the old pattern will fall short. When in doubt, enter the heavier hours figure and let the calculator show you the larger answer honestly. Our sump pump guide covers the same duty-cycle check as part of sizing for a specific pump.
Running watts vs starting watts: the surge warning
The watts in this calculator are running watts: what the pump draws while it is moving water. When the motor first kicks on, it draws a short startup surge of about 3 to 7 times its running watts for a fraction of a second. Using the ranges from our sump pump guide: a 1/3 HP pump runs about 800 to 1,000W, a 1/2 HP pump about 1,000 to 1,500W, and a 3/4 HP pump about 1,500 to 2,000W. At those running figures, surge is the real gatekeeper: a 1,000W pump can surge to roughly 3,000 to 5,000W at startup. The exact figure for your pump is the locked-rotor amps (LRA) on its motor label, multiplied by 120 volts; running watts are the label amps multiplied by 120 the same way.
Be transparent about what the calculator checks: its peak check compares each station’s continuous output against your total entered running load. It does not, and cannot, check the startup surge, because surge depends on the individual motor. You must still confirm a station’s surge capability for motor startup yourself before relying on it: compare the station’s surge rating against your pump’s LRA figure, not against its running watts. This is why the honest pattern on this page is narrow. Per our guide, starting a typical sump pump reliably takes a station rated at least 2,400W continuous output with a surge rating that clears the pump’s locked-rotor draw, which in our catalog is only the EcoFlow Delta 2 Max (2,048Wh, 2,400W continuous, 3,400W X-Boost). A pump whose surge passes about 4,000W, common on 3/4 HP units, is generator territory, full stop.
Why inverter output can be the limit, not capacity
Capacity and output are separate gates, and a station has to clear both. Capacity (watt-hours) decides how long the pump runs; output (watts) decides whether it runs at all. Consider a light-rain day: an 800W pump running 1 hour in total needs only 800Wh, which fits the usable capacity of several stations in our catalog on paper. But the smallest of them, the EcoFlow River 2 Pro, pairs its 653Wh of usable capacity with an 800W output that sits exactly at the pump’s running draw and far under its startup surge, so it is not a sump pump station however the capacity math looks. Step the pump up to a 1,500W 3/4 HP unit running half an hour a day and the energy need is just 750Wh, a small number that five of our six stations could hold, yet only the 2,400W Delta 2 Max clears even the running load with any margin.
The calculator applies both gates the way it can: it only recommends a station whose usable capacity covers your watt-hours and whose continuous output covers your entered running peak. What it cannot apply is the third gate, the surge, which is why the recommendation on this page is a starting point for the surge check above, not the end of it. When a station fails the output gate, adding capacity does not help; when it fails the capacity gate, adding output does not help. Sump pumps are the load where buyers most often check only one of the three.
A worked outage example
Take a 1/2 HP pump labeled at 9 running amps, the worked example from our sump pump guide: 9 amps x 120 = 1,080W running, with 28 locked-rotor amps, a surge of about 3,360W. During heavy rain it runs 20 minutes per hour, which converts to about 8 hours of pump-on time a day. The energy math is 1,080W x 8 hours = 8,640Wh per day, a rated capacity need of about 10,165Wh. Enter those figures above (1,080W, 8 hours) and the calculator says what it should: no station we link to covers a full day of that storm. The Delta 2 Max, the biggest we link to, covers about 1.6 pump-on hours per charge, roughly 4.8 wall-clock hours at that 20-minutes-per-hour pattern, and its 2,400W continuous output with a surge check against the pump’s 3,360W figure is a separate conversation the buyer has to have with the spec sheet.
That example is the reason this page exists alongside the guide. A station is a bridge for a sump pump: it covers the first hours of an outage silently and automatically, it covers lighter storms outright, and for a long outage in heavy rain it buys time to get a generator running or the grid back. Our power outage guide covers how a station fits the wider outage kit (fridge, lights, phones, router) once the pump’s share is understood. What a station is not, at any size we link to, is a multi-day sump pump plan for a house whose basement floods when the pump stops.
Worked examples
- The preloaded storm case: 800W x 4 hours = 3,200Wh per day. A rated need of about 3,765Wh. No station we link to covers a full day; the Delta 2 Max covers about 13 hours of that daily pattern per charge, about 2.2 pump-on hours. This is the normal result for storm-duty sump sizing, not an error.
- Light rain: 800W x 1 hour = 800Wh. Change the hours to 1 (about 2 to 3 minutes per hour) and the need drops to about 941Wh rated. The EcoFlow Delta 2 is the smallest station we link to that covers it, with the BLUETTI Elite 100 V2 shown with more headroom, both by roughly 9 percent of usable capacity. The surge check still applies before either is a real answer.
- A moderate day: 800W x 2 hours = 1,600Wh. About 1,882Wh rated. Only the Delta 2 Max covers it in our catalog, with roughly 9 percent to spare. Two hours a day is about 5 minutes per hour, unremarkable rain, which shows how quickly sump loads outgrow mid-size stations.
- Heavy rain on the preload pump: 800W x 8 hours = 6,400Wh. Twenty minutes per hour doubles the preloaded day. No station we link to covers it; the Delta 2 Max covers about 6.5 hours of that pattern. At this duty cycle the limiting factor stops being the battery and becomes the plan: recharge windows, a generator, or a dedicated battery-backup sump system.
- Pump plus fridge: 3,200Wh + 1,500Wh = 4,700Wh per day. Add a refrigerator row (150W x 10 hours) to the preloaded pump and the combined day passes every station we link to by a wide margin. In a real outage, sequence the loads if you can: the pump is not optional while it is raining, and an unopened fridge holds its temperature for hours without power.
The seven stations this calculator can recommend
Recommendations come only from the same seven stations as our main Power Station Size Calculator, with manufacturer specifications, pictured cards, and current check-price links: EcoFlow River 2 Pro (768Wh, 800W output, about 18.2 lbs), EcoFlow Delta 2 (1,024Wh, 1,800W, about 27 lbs), BLUETTI Elite 100 V2 (1,024Wh, 1,800W, about 25.3 lbs), Anker Solix C1000 Gen 2 (1,024Wh, 2,000W, about 24.9 lbs), Jackery Explorer 1000 v2 (1,070Wh, 1,500W, about 23.8 lbs), EcoFlow Delta 2 Max (2,048Wh, 2,400W, about 50 lbs), and BLUETTI Apex 200 (2,560Wh, 3,200W output, about 59.3 lbs). Read against sump loads, the honest summary is short: the four 1,000Wh-class stations earn their place on light-rain days and short bridges, their outputs sit under most pumps’ startup surges, and the Delta 2 Max is the only station in the catalog our sump pump guide rates as a minimum viable option for actually starting a typical pump. If none of them covers your watts, hours, and days, the calculator says so and shows the biggest station we link to and what it actually covers, instead of stretching a smaller station into a fit. Expect that no-fit result often on this page; it is the calculator working as designed.
Mistakes to avoid
- Entering 24 hours. That prices the pump as if it never cycles off. A pump runs minutes per hour, not around the clock; convert your timed minutes per hour to hours per day (10 minutes per hour = 4 hours a day) and enter that.
- Checking capacity and forgetting the surge. A station can hold enough watt-hours and still fail to start the motor. The calculator checks output against running watts only; confirm the station’s surge rating against your pump’s locked-rotor amps yourself.
- Sizing for average rain. The battery has to survive the peak of the storm, when inflow and pump-on minutes are at their highest and the outage is most likely. Time your pump during heavy rain, not on a drizzle day.
- Forgetting the 85 percent factor. A 2,048Wh station delivers about 1,741Wh to your pump after conversion losses. The calculator applies this for you, but it is why a station that looks big enough on its box falls short in a storm.
- Assuming an unknown pump is small. If you do not know your pump’s size, our guide’s planning figure is 1,000W, not the 800W preload here, and the label on the motor settles it: amps x 120 = watts.
- Skipping the dry test. Test the station starting your exact pump before you need it in a storm, with the pit at a normal level. An inverter that trips on startup is a discovery to make on a dry afternoon, not at 2 a.m. in a downpour.
- Treating the station as the whole plan. For a basement that floods when the pump stops, a station is one layer. A dedicated battery-backup sump system and, for long outages, a generator are the other layers our guide lays out.
Questions and answers
What size power station do I need to run a sump pump? Start with the two gates. On capacity: an 800W pump running 4 hours a day needs about 3,200Wh of usable power, about 3,765Wh rated, which no single station we link to holds for a full storm day; the 2,048Wh Delta 2 Max covers about 13 hours of that pattern. On output and surge: per our guide, plan on at least 2,400W continuous output and a surge rating that clears your pump’s locked-rotor draw. In lighter rain (1 to 2 run-hours a day) the same pump needs 800 to 1,600Wh, which the 1,024Wh class or the Delta 2 Max covers on capacity.
How long will a 2,000Wh-class station run my sump pump? A 2,048Wh station delivers about 1,741Wh usable. Against an 800W pump that is about 2.2 hours of pump-on time, which the duty cycle spreads across roughly 13 wall-clock hours at 10 minutes per hour, or about 6.5 hours at 20 minutes per hour. Against a 1,080W pump it is about 1.6 pump-on hours. Heavier inflow shortens every one of those figures.
Why does the calculator use 4 hours instead of 24? Because the pump cycles. Four hours is run-time equivalent: the total time the pump is actually drawing power across a day when it runs about 10 minutes per hour. The pit is being emptied around the clock; the pump only draws its running watts for about 4 of those hours. Entering 24 hours would price a pump that never rests, which no real pump does outside a flood it is already losing to.
Can a 1,000Wh-class station run a sump pump? On capacity, only in light conditions: about 800Wh of need (an 800W pump at 1 hour a day) fits, and the calculator will show the Delta 2 for it. On starting, be careful: 1,500 to 1,800W of continuous output is under the startup surge of most 1/3 and 1/2 HP pumps, so a capacity fit is not a starting guarantee. Test your exact pump on any station before a storm, and treat the Delta 2 Max class as the realistic starting point for unattended storm duty.
Why does the calculator so often say no station fits? Because storm-duty sump pumping is one of the heaviest household loads there is: 3,200Wh a day at the preload, 6,400Wh in heavy rain, past the usable capacity of the largest station we link to, the 2,560Wh BLUETTI Apex 200. Rather than stretch a recommendation, the calculator shows that largest station and how much of your pattern it actually covers, so you can plan a recharge window, fewer hours, or a generator layer.
Is a power station or a generator better for a sump pump? For long outages and heavy storms, a generator is the better tool: it clears the surge easily and refuels. A station wins as the instant, silent, indoor-safe bridge for the first hours, for short outages, and where a generator is impractical. Many houses that flood easily end up with both, plus a dedicated battery-backup sump system. Our sump pump guide lays out that comparison in full.
Related calculators
Sizing a different single load instead? The Refrigerator Power Station Calculator is preloaded with a typical full-size fridge at 150W and 10 hours of compressor run-time a day, and the CPAP Power Station Calculator is preloaded with a CPAP machine at 60W for 8 hours a night, with the humidifier math that decides CPAP sizing.
Sizing a mixed load, or the pump plus a whole outage kit, rather than the pump alone? Run the full device list through the Power Station Size Calculator, then read the power outage guide for the picks and features that matter when the grid is down.